Plumbing Inspection Section#3 Drain, Waste and Vent Plumbing Test#3

  • Question 1

    1 out of 1 points
    Correct
    A French drain is
    Selected Answer:
    Correct 
    a gravel pit below grade
    Answers:
    Correct 
  • Question 2

    1 out of 1 points
    Correct
    A waste plumbing pipe is considered vertical if it has
    Selected Answer:
    Correct 
    45°+ slope from horizontal
    Answers:
    Correct 
  • Question 3

    1 out of 1 points
    Correct
    To meet the Standards we have to inspect
    Selected Answer:
    Correct 
    drainage sumps, sump pumps and related plumbing
    Answers:
    Correct 
  • Question 4

    1 out of 1 points
    Correct
    A trap primer in a plumbing system is
    Selected Answer:
    Correct 
    a tube from a fixture that lets water flow to the floor drain
    Answers:
    Correct 
  • Question 5

    1 out of 1 points
    Correct
    Double trapping is a problem because
    Selected Answer:
    Correct 
    the water velocity at the second trap is too low
    Answers:
    Correct 
  • Question 6

    1 out of 1 points
    Correct
    Laundry tub pumps differ from sump pumps because laundry tub pumps
    Selected Answer:
    Correct 
    can have a manual start switch
    Answers:
    Correct 
  • Question 7

    1 out of 1 points
    Correct
    One issue with plastic pipes in a waste plumbing system is
    Selected Answer:
    Correct 
    they are noisy
    Answers:
    Correct 
  • Question 8

    1 out of 1 points
    Correct
    Sewage ejector pumps are used
    Selected Answer:
    Correct 
    where waste cannot flow by gravity
    Answers:
    Correct 
  • Question 9

    1 out of 1 points
    Correct
    A foot vent in a waste plumbing system is
    Selected Answer:
    Correct 
    used to vent an island sink
    Answers:
    Correct 
  • Question 10

    1 out of 1 points
    Correct
    The slope of a horizontal drain pipe in a waste plumbing system should be
    Selected Answer:
    Correct 
    1/4 inch to 1/2 inch per foot
    Answers:
    Correct 
  • Question 11

    1 out of 1 points
    Correct
    When plumbing vents extend more than 12 to 24 inches above the roof line, there is a danger of
    Selected Answer:
    Correct 
    frost closure in cold climates
    Answers:
    Correct 
  • Question 12

    1 out of 1 points
    Correct
    Vents between the fixture and the trap on a waste plumbing system
    Selected Answer:
    Correct 
    may allow sewer gas to enter the house
    Answers:
    Correct 
  • Question 13

    0 out of 1 points
    Incorrect
    Sump pumps may run continuously for the following reasons EXCEPT
    Selected Answer:
    Incorrect 
    the float may be stuck
    Answers:
    Correct 
  • Question 14

    1 out of 1 points
    Correct
    In multi-family buildings, PVC or ABS plastic waste piping should not pass from one dwelling to the next because
    Selected Answer:
    Correct 
    fire separation may be compromised
    Answers:
    Correct 
  • Question 15

    1 out of 1 points
    Correct
    The tail piece in a waste plumbing system is
    Selected Answer:
    Correct 
    the pipe that joins the fixture to the trap
    Answers:
    Correct 
  • Question 16

    0 out of 1 points
    Incorrect
    Water passing through a waste plumbing trap too quickly may
    Selected Answer:
    Incorrect 
    leave behind solids
    Answers:
    Correct 
  • Question 17

    0 out of 1 points
    Incorrect
    All of the following drainage situations would be considered functional EXCEPT
    Selected Answer:
    Incorrect 
    2nd floor bathroom sink takes 25 seconds to drain
    Answers:
    Correct 
  • Question 18

    1 out of 1 points
    Correct
    The best residential waste plumbing trap is a
    Selected Answer:
    Correct 
    P trap
    Answers:
    Correct 
  • Question 19

    1 out of 1 points
    Correct
    A loop vent in a waste plumbing system
    Selected Answer:
    Correct 
    is one method of venting an island sink
    Answers:
    Correct 
  • Question 20

    0 out of 1 points
    Incorrect
    Water passing through a waste plumbing trap too slowly may cause
    Selected Answer:
    Incorrect 
    clogs in the vent line
    Answers:
    Correct 
  • Question 21

    1 out of 1 points
    Correct
    Toilets are unique plumbing fixtures because they
    Selected Answer:
    Correct 
    are self trapped
    Answers:
    Correct 
  • Question 22

    1 out of 1 points
    Correct
    Vent pipes differ from waste pipes in a plumbing system in that
    Selected Answer:
    Correct 
    traps are not required
    Answers:
    Correct 
  • Question 23

    1 out of 1 points
    Correct
    Waste plumbing traps that do not have a separate vent can generally be a maximum distance of __________ from the stack?
    Selected Answer:
    Correct 
    5 feet
    Answers:
    Correct 
  • Question 24

    0 out of 1 points
    Incorrect
    If a cool draft with no sewer odor is felt at a floor drain, the likely cause is
    Selected Answer:
    Incorrect 
    air blowing down the stack
    Answers:
    Correct 
  • Question 25

    1 out of 1 points
    Correct
    The main purpose of a trap is to
    Selected Answer:
    Correct 
    prevent sewer gas from entering the house
    Answers:
    Correct 