Describe a standpipe for a clotheswasher drain.Selected Answer: 1. Vertical pipe that receives the clothes washer drain hose2. A trap3. A trap arm that attaches to a vented stackCorrect Answer: A vertical pipe that receives the clothes washer drain hose, a trap, and a trap arm that attaches to a vented stack.Response Feedback: [None Given] Question 2
List the five manufacturers? names you may find stamped on defective ABS pipe.Selected Answer: 1. Centaur (Phoenix)2. Gable3. Polaris4. ApaCorrect Answer: Centaur, Phoenix, Gable, Polaris, ApacheResponse Feedback: [None Given] Question 3
What is the implication of poor manifolding?Selected Answer: clogging of pCorrect Answer: Clogging of pipesResponse Feedback: [None Given] Question 4
What is the purpose of an air gap in a dishwasher drain?Selected Answer: This air gap fitting prevents contamination of the potable water supply where it joins the dishwasher in the event that waste backs up through the dishwasther drain hose.Correct Answer: To prevent a cross connectionResponse Feedback: [None Given] Question 5
Where should the condensate drain from an air conditioner discharge?Selected Answer: An indirect waste using an air gap must be provided.Correct Answer: To a fixture drain, upstream of the fixture trap, into the overflow connection of a tub, or onto a floor drain grate, with an air gap.Response Feedback: [None Given] Question 6
Why is PVC or ABS plastic piping allowed only in single family homes usually?Selected Answer: Because they are combustibleCorrect Answer: It is combustibleResponse Feedback: [None Given] Question 7
Why is the standpipe for a clotheswasher drain necessary?Selected Answer: To avoid cross connectionCorrect Answer: This standpipe arrangement prevents a cross connection that occurs when the washer drain hose is hooked over the side of a laundry tub.Response Feedback: [None Given] Question 8
When was defective ABS plastic drain, waste and vent piping manufactured?Selected Answer: 1985 to 1986Answers: Response Feedback: Good workQuestion 9
Pipe size should always increase as you move downstream and more fixtures join in.Selected Answer: True
Answers: True
FalseResponse Feedback: Good work