Friday, August 21, 2015

Electricity Inspection Section#3 The Distribution System Quiz#5

You should have finished Study Session 4 before starting this study session. This study session deals with switches and junction boxes, and touches on smoke detectors.
The estimated completion time is 30 minutes.
Objectives
At the end of this study session, you should be able to:
  • Describe the function of switches and junction boxes and the common operating conditions.
  • Describe the causes and implications of the conditions.
  • Explain how to inspect these systems.
  • Question 1

    Needs Grading
    How would you identify an obsolete switch?
    Selected Answer:
    Early switches have two round push buttons
    Correct Answer:
    Correct 
    An obsolete switch is typically a round, push-button switch.
  • Question 2

    Needs Grading
    List 10 common problems found with switches.
    Selected Answer:
    1. Damaged
    2. Loose
    3. Overheating
    4. Inoperative
    5. Obsolete
    6. Poor location near furnace
    7. Poor location in bathroom
    8. Faulty three-way or four-way switches
    9. Dimmer switches without positive shut off
    10. Garbage disposal problems
    Correct Answer:
    Correct
    1. Damaged 2. Loose 3. Overheating 4. Inoperative 5. Obsolete 6. Poor location near furnace 7. Poor location in bathroom 8. Faulty three-way or four-way switches. 9. Dimmer switches without positive shut-off 10. Poor switch location for garbage disposal
  • Question 3

    Needs Grading
    List 8 common junction box problems.
    Selected Answer:
    1. Damaged
    2. Missing
    3. Loose
    4. Overheating
    5. Not grounded
    6. Cover loose or missing
    7. Crowded
    8. Concealed boxes
    Correct Answer:
    Correct 
    1. Damaged 2. Missing 3. Loose 4. Overheating 5. Not grounded 6. Cover loose or missing 7. Crowded 8. Concealed boxes
  • Question 4

    Needs Grading
    Name two types of smoke detectors.
    Selected Answer:
    ionization detectors
    photoelectric detectors
    Correct Answer:
    Correct 
    Ionization and photoelectric
  • Question 5

    Needs Grading
    What connections do not need to be inside junction boxes?
    Selected Answer:
    Knob-and-tube wiring
    Correct Answer:
    Correct 
    Fluorescent light boxes and original knob-and-tube wiring connections.
  • Question 6

    Needs Grading
    What is a common problem with dimmer switches?
    Selected Answer:
    You could adjust the light to so low that no one thinks it is on. 
    Correct Answer:
    Correct 
    No positive shut-off.
  • Question 7

    Needs Grading
    What is a traveler in the context of a 3-way switch?
    Selected Answer:
    Wires runs between the two three-way switches is usually called traveler. 
    Correct Answer:
    Correct 
    The traveler is typically the three-conductor cable between the two switches.
  • Question 8

    0 out of 0 points
    All junction boxes should be concealed.
    Selected Answer:
    Incorrect True
    Correct Answer:
    Correct False
  • Question 9

    0 out of 0 points
    Knob-and-tube wiring was installed without junction boxes commonly.
    Selected Answer:
    Correct True
    Correct Answer:
    Correct True
  • Question 10

    0 out of 0 points
    One smoke detector is needed in each home, near the kitchen because that's where most house fires start.
    Selected Answer:
    Correct False
    Correct Answer:
    Correct False

No comments: