Heating I Test#1 Gas Furnace

  • ·         Question 1
    0.5 out of 0.5 points
    Description: Correct
    A vent connector on a conventional gas furnace should slope up and away from the furnace at a minimum of
    Selected Answer:
    Description: Correct 
    1/4 inch per foot
    Answers:
    Description: Correct 
    1/4 inch per foot
    1/2 inch per foot
    3/4 inch per foot
    5/8 inch per foot
    1 inch per foot
    ·         Question 2
    0.5 out of 0.5 points
    Description: Correct
    Heat exchanger failure in a conventional gas furnace may lead to all of these EXCEPT
    Selected Answer:
    Description: Correct 
    scorching on the heat shield
    Answers:
    carbon monoxide in the house
    Description: Correct 
    scorching on the heat shield
    short cycling of the furnace
    high house humidity levels
    flame pattern disruption when the house air fan comes on
    ·         Question 3
    0.5 out of 0.5 points
    Description: Correct
    As a general rule, a vent connector's length on a conventional gas furnace should be no more than
    Selected Answer:
    Description: Correct 
    75% of the chimney height
    Answers:
    Description: Correct 
    75% of the chimney height
    50% of the chimney height
    30% of the chimney height
    25% of the chimney height
    10% of the chimney height
    ·         Question 4
    0.5 out of 0.5 points
    Description: Correct
    Mid-efficiency gas furnaces
    Selected Answer:
    Description: Correct 
    use a chimney
    Answers:
    have a draft hood
    Description: Correct 
    use a chimney
    produce condensation
    have unusual heat exchangers
    do not accommodate air conditioning coils
    ·         Question 5
    0.5 out of 0.5 points
    Description: Correct
    All of the following are common problems with flexible connectors for gas appliances EXCEPT
    Selected Answer:
    Description: Correct 
    less than 6 feet long
    Answers:
    concealed connections
    Description: Correct 
    less than 6 feet long
    run through wall framing
    run through floor framing
    shut off valve not in same room as appliance
    ·         Question 6
    0.5 out of 0.5 points
    Description: Correct
    The high limit setting for a conventional forced air gas furnace is typically
    Selected Answer:
    Description: Correct 
    200°F
    Answers:
    70°F
    100°F
    150°F
    Description: Correct 
    200°F
    250°F
    ·         Question 7
    0.5 out of 0.5 points
    Description: Correct
    Vertical steel gas piping should be supported
    Selected Answer:
    Description: Correct 
    at every floor
    Answers:
    Description: Correct 
    at every floor
    every 6 feet
    every 10 feet
    every 12 feet
    only at connection points
    ·         Question 8
    0.5 out of 0.5 points
    Description: Correct
    All of the following are common problems on house air fans EXCEPT
    Selected Answer:
    Description: Correct 
    missing
    Answers:
    dirty
    damaged
    noisy
    inoperative
    Description: Correct 
    missing
    ·         Question 9
    0.5 out of 0.5 points
    Description: Correct
    The fan/limit switch will typically turn the blower on at
    Selected Answer:
    Description: Correct 
    120 - 150°F
    Answers:
    60 - 90°F
    90 - 120°F
    Description: Correct 
    120 - 150°F
    150 - 200°F
    200 - 250°F
    ·         Question 10
    0.5 out of 0.5 points
    Description: Correct
    The most serious implication of a leaking humidifier on a furnace is
    Selected Answer:
    Description: Correct 
    rusting of the heat exchanger
    Answers:
    poor comfort
    noisy
    Description: Correct 
    rusting of the heat exchanger
    rusted ducts
    damage to interior furnishings
    ·         Question 11
    0.5 out of 0.5 points
    Description: Correct
    How many panel covers do most conventional gas furnaces have?
    Selected Answer:
    Description: Correct 
    2
    Answers:
    1
    Description: Correct 
    2
    3
    4
    5
    ·         Question 12
    0.5 out of 0.5 points
    Description: Correct
    Which of the following natural gas piping arrangements is not permitted?
    Selected Answer:
    Description: Correct 
    plastic piping indoors
    Answers:
    copper piping indoors
    plastic piping below grade
    steel piping indoors
    Description: Correct 
    plastic piping indoors
    steel piping outdoors
    ·         Question 13
    0.5 out of 0.5 points
    Description: Correct
    When inspecting a heating system according to the Standards, the home inspector must observe all of the following EXCEPT
    Selected Answer:
    Description: Correct 
    the furnace heat exchanger
    Answers:
    chimneys
    vent systems
    Description: Correct 
    the furnace heat exchanger
    installed heating equipment
    flues
    ·         Question 14
    0.5 out of 0.5 points
    Description: Correct
    All of the following are true EXCEPT
    Selected Answer:
    Description: Correct 
    heat exchanger cracks are usually detectible during a home inspection
    Answers:
    weak airflow is usually detectible during a home inspection
    flue collars are usually visible during a home inspection
    vent connector lengths between 5 and 10 feet are acceptable
    Description: Correct 
    heat exchanger cracks are usually detectible during a home inspection
    it is possible to test a furnace in the summer
    ·         Question 15
    0.5 out of 0.5 points
    Description: Correct
    Generally, vent connectors for conventional gas furnaces should be supported every
    Selected Answer:
    Description: Correct 
    4 feet and at every elbow
    Answers:
    2 feet and at every elbow
    3 feet and at every elbow
    Description: Correct 
    4 feet and at every elbow
    8 feet
    10 feet
    ·         Question 16
    0.5 out of 0.5 points
    Description: Correct
    A gas meter installed inside a house will not
    Selected Answer:
    Description: Correct 
    have a regulator
    Answers:
    have a main valve
    be vulnerable to mechanical damage
    be vulnerable to leaks
    be undersized
    Description: Correct 
    have a regulator
    ·         Question 17
    0.5 out of 0.5 points
    Description: Correct
    In summer months, humidifiers in homes should be set to
    Selected Answer:
    Description: Correct 
    Off
    Answers:
    15%
    20%
    30%
    40%
    Description: Correct 
    Off
    ·         Question 18
    0.5 out of 0.5 points
    Description: Correct
    3/4 to 1 inch diameter steel horizontal gas piping should be supported at least every
    Selected Answer:
    Description: Correct 
    8 feet
    Answers:
    1 foot
    3 feet
    6 feet
    Description: Correct 
    8 feet
    10 feet
    ·         Question 19
    0.5 out of 0.5 points
    Description: Correct
    The seasonal efficiency of a conventional gas furnace is approximately
    Selected Answer:
    Description: Correct 
    60%
    Answers:
    Description: Correct 
    60%
    70%
    50%
    40%
    80%
    ·         Question 20
    0.5 out of 0.5 points
    Description: Correct
    All of the following may adversely affect the amount of air delivered to each room EXCEPT
    Selected Answer:
    Description: Correct 
    inadequate BTU rating
    Answers:
    dirty ducts
    dirty air conditioning coil
    Description: Correct 
    inadequate BTU rating
    dirty fan
    damaged ducts
    ·         Question 21
    0.5 out of 0.5 points
    Description: Correct
    The purpose of a heating inspection is to ensure that the system
    Selected Answer:
    Description: Correct 
    is safe and operating properly
    Answers:
    Description: Correct 
    is safe and operating properly
    meets current gas codes
    is high efficiency
    age is less than the normal life expectancy
    is sized to meet the heat loss
    ·         Question 22
    0.5 out of 0.5 points
    Description: Correct
    For complete combustion, and ignoring dilution air requirements, natural gas requires approximately
    Selected Answer:
    Description: Correct 
    1/15 volume ratio of gas/air
    Answers:
    1/150 volume ratio of gas/air
    1/100 volume ratio of gas/air
    1 pound of air for 1 pound of fuel
    Description: Correct 
    1/15 volume ratio of gas/air
    15/1 volume ratio of gas/air
    ·         Question 23
    0.5 out of 0.5 points
    Description: Correct
    A thermocouple
    Selected Answer:
    Description: Correct 
    detects the pilot flame
    Answers:
    Description: Correct 
    detects the pilot flame
    detects flame roll-out
    detects flashbacks
    detects carbon monoxide
    detects backdrafting
    ·         Question 24
    0.5 out of 0.5 points
    Description: Correct
    Vent connectors on conventional gas furnaces more than how many feet long should be considered suspect?
    Selected Answer:
    Description: Correct 
    10
    Answers:
    2
    5
    6
    8
    Description: Correct 
    10
    ·         Question 25
    0.5 out of 0.5 points
    Description: Correct
    A mechanical thermostat typically uses a bulb full of
    Selected Answer:
    Description: Correct 
    mercury
    Answers:
    nitrogen
    lead
    nickel
    Description: Correct 
    mercury
    copper