- · Question 10.5 out of 0.5 pointsA vent connector on a conventional gas furnace should slope up and away from the furnace at a minimum ofSelected Answer:1/4 inch per footAnswers:1/4 inch per foot1/2 inch per foot3/4 inch per foot5/8 inch per foot1 inch per foot· Question 20.5 out of 0.5 pointsHeat exchanger failure in a conventional gas furnace may lead to all of these EXCEPTSelected Answer:scorching on the heat shieldAnswers:carbon monoxide in the housescorching on the heat shieldshort cycling of the furnacehigh house humidity levelsflame pattern disruption when the house air fan comes on· Question 30.5 out of 0.5 pointsAs a general rule, a vent connector's length on a conventional gas furnace should be no more thanSelected Answer:75% of the chimney heightAnswers:75% of the chimney height50% of the chimney height30% of the chimney height25% of the chimney height10% of the chimney height· Question 40.5 out of 0.5 pointsMid-efficiency gas furnacesSelected Answer:use a chimneyAnswers:have a draft hooduse a chimneyproduce condensationhave unusual heat exchangersdo not accommodate air conditioning coils· Question 50.5 out of 0.5 pointsAll of the following are common problems with flexible connectors for gas appliances EXCEPTSelected Answer:less than 6 feet longAnswers:concealed connectionsless than 6 feet longrun through wall framingrun through floor framingshut off valve not in same room as appliance· Question 60.5 out of 0.5 pointsThe high limit setting for a conventional forced air gas furnace is typicallySelected Answer:200°FAnswers:70°F100°F150°F200°F250°F· Question 70.5 out of 0.5 pointsVertical steel gas piping should be supportedSelected Answer:at every floorAnswers:at every floorevery 6 feetevery 10 feetevery 12 feetonly at connection points· Question 80.5 out of 0.5 pointsAll of the following are common problems on house air fans EXCEPTSelected Answer:missingAnswers:dirtydamagednoisyinoperativemissing· Question 90.5 out of 0.5 pointsThe fan/limit switch will typically turn the blower on atSelected Answer:120 - 150°FAnswers:60 - 90°F90 - 120°F120 - 150°F150 - 200°F200 - 250°F· Question 100.5 out of 0.5 pointsThe most serious implication of a leaking humidifier on a furnace isSelected Answer:rusting of the heat exchangerAnswers:poor comfortnoisyrusting of the heat exchangerrusted ductsdamage to interior furnishings· Question 110.5 out of 0.5 pointsHow many panel covers do most conventional gas furnaces have?Selected Answer:2Answers:12345· Question 120.5 out of 0.5 pointsWhich of the following natural gas piping arrangements is not permitted?Selected Answer:plastic piping indoorsAnswers:copper piping indoorsplastic piping below gradesteel piping indoorsplastic piping indoorssteel piping outdoors· Question 130.5 out of 0.5 pointsWhen inspecting a heating system according to the Standards, the home inspector must observe all of the following EXCEPTSelected Answer:the furnace heat exchangerAnswers:chimneysvent systemsthe furnace heat exchangerinstalled heating equipmentflues· Question 140.5 out of 0.5 pointsAll of the following are true EXCEPTSelected Answer:heat exchanger cracks are usually detectible during a home inspectionAnswers:weak airflow is usually detectible during a home inspectionflue collars are usually visible during a home inspectionvent connector lengths between 5 and 10 feet are acceptableheat exchanger cracks are usually detectible during a home inspectionit is possible to test a furnace in the summer· Question 150.5 out of 0.5 pointsGenerally, vent connectors for conventional gas furnaces should be supported everySelected Answer:4 feet and at every elbowAnswers:2 feet and at every elbow3 feet and at every elbow4 feet and at every elbow8 feet10 feet· Question 160.5 out of 0.5 pointsA gas meter installed inside a house will notSelected Answer:have a regulatorAnswers:have a main valvebe vulnerable to mechanical damagebe vulnerable to leaksbe undersizedhave a regulator· Question 170.5 out of 0.5 pointsIn summer months, humidifiers in homes should be set toSelected Answer:OffAnswers:15%20%30%40%Off· Question 180.5 out of 0.5 points3/4 to 1 inch diameter steel horizontal gas piping should be supported at least everySelected Answer:8 feetAnswers:1 foot3 feet6 feet8 feet10 feet· Question 190.5 out of 0.5 pointsThe seasonal efficiency of a conventional gas furnace is approximatelySelected Answer:60%Answers:60%70%50%40%80%· Question 200.5 out of 0.5 pointsAll of the following may adversely affect the amount of air delivered to each room EXCEPTSelected Answer:inadequate BTU ratingAnswers:dirty ductsdirty air conditioning coilinadequate BTU ratingdirty fandamaged ducts· Question 210.5 out of 0.5 pointsThe purpose of a heating inspection is to ensure that the systemSelected Answer:is safe and operating properlyAnswers:is safe and operating properlymeets current gas codesis high efficiencyage is less than the normal life expectancyis sized to meet the heat loss· Question 220.5 out of 0.5 pointsFor complete combustion, and ignoring dilution air requirements, natural gas requires approximatelySelected Answer:1/15 volume ratio of gas/airAnswers:1/150 volume ratio of gas/air1/100 volume ratio of gas/air1 pound of air for 1 pound of fuel1/15 volume ratio of gas/air15/1 volume ratio of gas/air· Question 230.5 out of 0.5 pointsA thermocoupleSelected Answer:detects the pilot flameAnswers:detects the pilot flamedetects flame roll-outdetects flashbacksdetects carbon monoxidedetects backdrafting· Question 240.5 out of 0.5 pointsVent connectors on conventional gas furnaces more than how many feet long should be considered suspect?Selected Answer:10Answers:256810· Question 250.5 out of 0.5 pointsA mechanical thermostat typically uses a bulb full ofSelected Answer:mercuryAnswers:nitrogenleadnickelmercurycopper
No comments:
Post a Comment