Question 1
A French drain isSelected Answer:
a gravel pit below gradeAnswers:
Question 2
A waste plumbing pipe is considered vertical if it hasSelected Answer:
45°+ slope from horizontalAnswers:
Question 3
To meet the Standards we have to inspectSelected Answer:
drainage sumps, sump pumps and related plumbingAnswers:
Question 4
A trap primer in a plumbing system isSelected Answer:
a tube from a fixture that lets water flow to the floor drainAnswers:
Question 5
Double trapping is a problem becauseSelected Answer:
the water velocity at the second trap is too lowAnswers:
Question 6
Laundry tub pumps differ from sump pumps because laundry tub pumpsSelected Answer:
can have a manual start switchAnswers:
Question 7
One issue with plastic pipes in a waste plumbing system isSelected Answer:
they are noisyAnswers:
Question 8
Sewage ejector pumps are usedSelected Answer:
where waste cannot flow by gravityAnswers:
Question 9
A foot vent in a waste plumbing system isSelected Answer:
used to vent an island sinkAnswers:
Question 10
The slope of a horizontal drain pipe in a waste plumbing system should beSelected Answer:
1/4 inch to 1/2 inch per footAnswers:
Question 11
When plumbing vents extend more than 12 to 24 inches above the roof line, there is a danger ofSelected Answer:
frost closure in cold climatesAnswers:
Question 12
Vents between the fixture and the trap on a waste plumbing systemSelected Answer:
may allow sewer gas to enter the houseAnswers:
Question 13
Sump pumps may run continuously for the following reasons EXCEPTSelected Answer:
the float may be stuckAnswers:
Question 14
In multi-family buildings, PVC or ABS plastic waste piping should not pass from one dwelling to the next becauseSelected Answer:
fire separation may be compromisedAnswers:
Question 15
The tail piece in a waste plumbing system isSelected Answer:
the pipe that joins the fixture to the trapAnswers:
Question 16
Water passing through a waste plumbing trap too quickly maySelected Answer:
leave behind solidsAnswers:
Question 17
All of the following drainage situations would be considered functional EXCEPTSelected Answer:
2nd floor bathroom sink takes 25 seconds to drainAnswers:
Question 18
The best residential waste plumbing trap is aSelected Answer:
P trapAnswers:
Question 19
A loop vent in a waste plumbing systemSelected Answer:
is one method of venting an island sinkAnswers:
Question 20
Water passing through a waste plumbing trap too slowly may causeSelected Answer:
clogs in the vent lineAnswers:
Question 21
Toilets are unique plumbing fixtures because theySelected Answer:
are self trappedAnswers:
Question 22
Vent pipes differ from waste pipes in a plumbing system in thatSelected Answer:
traps are not requiredAnswers:
Question 23
Waste plumbing traps that do not have a separate vent can generally be a maximum distance of __________ from the stack?Selected Answer:
5 feetAnswers:
Question 24
If a cool draft with no sewer odor is felt at a floor drain, the likely cause isSelected Answer:
air blowing down the stackAnswers:
Question 25
The main purpose of a trap is toSelected Answer:
prevent sewer gas from entering the houseAnswers:
Saturday, December 19, 2015
Plumbing Inspection Section#3 Drain, Waste and Vent Plumbing Test#3
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment