Plumbing Inspection Section#3 Drain, Waste and Vent Plumbing Quiz#6

You should have finished Study Session 5 before starting this study session. This study session deals with floor drains and the venting system.
The estimated completion time is one to one and a half hours.
Objectives
At the end of this study session, you should be able to:
  • List seven problems commonly found with floor drains.
  • Describe the function of the vent system.
  • List common materials used in the vent system.
  • Describe the simple tests used to check whether the venting system is working.
  • List seven common problems found with the venting system.
  • Question 1

    Needs Grading
    Ungraded
    Explain briefly the problems with venting kitchen island sinks.
    Selected Answer:
    most home owners don't want vents running up through the middle of their kitchen. 
    Correct Answer:
    Correct
    Kitchen islands are not adjacent to walls; therefore the vent pipe is some distance from the island, often exceeding the maximum allowable distance between trap and vent.
    Response Feedback:[None Given]
  • Question 2

    Needs Grading
    Ungraded
    Explain briefly the simple test required to check the venting system when you test functional drainage from a fixture.
    Selected Answer:
    flow water at each fixture
    Correct Answer:
    Correct 
    Listen for gurgling as the last bit of water leaves the drain, and smell for sewer odors.
    Response Feedback:[None Given]
  • Question 3

    Needs Grading
    Ungraded
    Explain the purpose of a backwater valve.
    Selected Answer:
    it is design to protect home against sewer backup
    Correct Answer:
    Correct 
    To protect the home against sewer back up.
    Response Feedback:[None Given]
  • Question 4

    Needs Grading
    Ungraded
    How high can a wet vent extend?
    Selected Answer:
    1 story
    Correct Answer:
    Correct 
    Over one floor level
    Response Feedback:[None Given]
  • Question 5

    Needs Grading
    Ungraded
    List five common materials used in venting systems.
    Selected Answer:
    copper
    galvanized steel
    cast iron
    ABS 
    PVC
    Correct Answer:
    Correct 
    1. Copper 2. Galvanized steel 3. Cast iron 4. ABS plastic 5. PVC plastic
    Response Feedback:[None Given]
  • Question 6

    Needs Grading
    Ungraded
    List seven problems found with vents.
    Selected Answer:
    1. Missing
    2. Ineffective
    3. Poor vent pipe arrangements
    4. Too small or too big
    5. Island venting problems
    6. Vent termination problems
    7. Automatic air vents
    Correct Answer:
    Correct
    1. Missing 2. Ineffective/incomplete 3. Poor vent pipe arrangements 4. Too small or too long 5. Island venting problems 6. Vent termination problems 7. Automatic air vents.
    Response Feedback:[None Given]
  • Question 7

    Needs Grading
    Ungraded
    List three reasons a floor drain may back up.
    Selected Answer:
    1. Overloaded storm sewer at the street (combination sewers)
    2. An obstructed or broken storm sewer for the house
    3. A clogged, collapsed or borken trap or drain pipe
    Correct Answer:
    Correct 
    1. Overloaded storm sewers at the street 2. Obstructed or broken storm sewer for the house 3. A clogged, collapsed or broken trap or drain pipe
    Response Feedback:[None Given]
  • Question 8

    Needs Grading
    Ungraded
    What function of the venting system does the automatic air vent not serve?
    Selected Answer:
    it doesn't allow air to be pushed out through the vent
    Correct Answer:
    Correct
    Automatic air vents do not allow air to be pushed out through the vent, an action which is sometimes necessary in order to equalize air pressure in the plumbing system.
    Response Feedback:[None Given]
  • Question 9

    Needs Grading
    Ungraded
    What is an automatic air vent?
    Selected Answer:
    It allows air to be drawn in when waste plumbing system in that area is under negative pressure. 
    Correct Answer:
    Correct
    An automatic air vent is a spring loaded device which allow air to be drawn in when the waste piping is under negative pressure, but will close when the waste pipe is under positive pressure so water cannot leak out.
    Response Feedback:[None Given]
  • Question 10

    Needs Grading
    Ungraded
    What is the maximum height of vent pipe above the roof line?
    Selected Answer:
    12 to 24 inches
    Correct Answer:
    Correct 
    12 inches
    Response Feedback:[None Given]
  • Question 11

    Needs Grading
    Ungraded
    What is the minimum vent diameter in cold climate areas above the roof line?
    Selected Answer:
    3 inch
    Correct Answer:
    Correct 
    3 inches
    Response Feedback:[None Given]
  • Question 12

    Needs Grading
    Ungraded
    What is the purpose of the venting system?
    Selected Answer:
    equilize air pressure in the waste plumbing system
    Correct Answer:
    Correct 
    To equalize the air pressure in the waste plumbing system so that the traps won?t siphon.
    Response Feedback:[None Given]
  • Question 13

    Needs Grading
    Ungraded
    Where should the floor drain be located?
    Selected Answer:
    they should be at the lowest point in the floor
    Correct Answer:
    Correct 
    At the low point in the floor
    Response Feedback:[None Given]
  • Question 14

    0 out of 0 points
    Correct
    How far can a vent be from an operable door?
    Selected Answer:
    Correct 
    3 feet
    Answers:
    Correct 
    Response Feedback:
    Good work
  • Question 15

    0 out of 0 points
    Correct
    Nearly horizontal vent pipes should slope slightly down away from the trap they are protecting.
    Selected Answer:
    Correct False
    Answers:
    True
    Correct False
    Response Feedback:
    Good work
  • Question 16

    0 out of 0 points
    Correct
    The vent diameter must be as large as the trap diameter.
    Selected Answer:
    Correct False
    Answers:
    True
    Correct False
    Response Feedback:
    Good work
  • Question 17

    0 out of 0 points
    Correct
    The vent is typically located upstream of the trap.
    Selected Answer:
    Correct False
    Answers:
    True
    Correct False
    Response Feedback:
    Good work