The estimated completion time is one to one and a half hours.
Objectives
At the end of this study session, you should be able to:
At the end of this study session, you should be able to:
- List eight problems commonly found with gas burners.
- List eleven problems commonly found with venting systems for gas burners.
Question 1
Briefly describe how you would check for spillage at the draft hood when testing the water heater.Selected Answer: Make sure that exhaust products are not spilling out of the draft hood for more than a minute or so on initial start up. Once the unit has been running for about two minutes, air flow should be into, not out of, the draft hood.Correct Answer: Once the water heater has been running for 2 minutes, place your hand at the draft hood opening. Spillage is wet heat that passes across your hand.Response Feedback: [None Given] Question 2
Describe a B Vent type vent connector.Selected Answer: B vent is a double-wall vent. It has air space between walls, a 1 inch clearance if all that is requiredCorrect Answer: B Vent are double-wall vents with an space between the walls.Response Feedback: [None Given] Question 3
List five common gas venting system problems.Selected Answer: 1. Rust2. Poor slope3. Poor support4. Poor connections5. Spillage at the draft hood6. Vent connector too small or too big for water heater7. Vent connector too longCorrect Answer: 1. Rust 2. Poor slope 3.Vent connector too long 4. Poor support 5. Poor connections 6. Inadequate clearance from combustibles 7. Vent connector too big or small 8. Improper material 9. Poor manifolding 10. Vent connector extends too far into chimney 11. Spillage at the draft hoodResponse Feedback: [None Given] Question 4
List five problems found with gas burners.Selected Answer: 1. Inoperative2. Scorching3. Poor flame color pattern4. Rust5. Dirt or soot6. Gas odor or leakCorrect Answer: 1. Inoperative 2. Scorching 3. Poor flame color pattern 4. Rust 5. Dirt or soot 6. Gas odor or leakResponse Feedback: [None Given] Question 5
List three causes of poor combustion.Selected Answer: 1. The room the water heater is in can't provide adequate combustion and dilution air2. The house is too tight3. There are too many appliances that consumes combustion and dilution airCorrect Answer: 1. Burners that are dirty, damaged or rusted 2. A poor fuel/air mixture 3. An inappropriate firing rate 4. An improper draft condition in the venting systemResponse Feedback: [None Given] Question 6
List three reasons for the problem of flame roll out or flashback.Selected Answer: 1. Overfiring of the burner2. Lack of combustion air supply3. A chimney obstruction or downdraft4. Underfiring of the burnerCorrect Answer: 1. Over firing of the burner 2. Lack of combustion air supply 3. A chimney obstruction or down draft 4. Underfiring of the burnerResponse Feedback: [None Given] Question 7
List three things that indicate poor flame colour or pattern.Selected Answer: 1. A burner that is dirty, damaged or rusted2. A poor fuel or air mixture3. An inappropriate firing rate4. Improper draft condition in the venting system (chimney)Correct Answer: 1. Yellow flame 2. Flame is lifting off the burner 3. Flame is not vertical 4. Flame is lazy or floating 5. Flame wanders around burnerResponse Feedback: [None Given] Question 8
Rusting above the flame roll out shield cover plate is a common sign of:Selected Answer: SpillageCorrect Answer: Flame roll out or flashbackResponse Feedback: [None Given] Question 9
What are the two functions of the draft hood?Selected Answer: 1. Add air to maintain chimney draft2. Deflect downdraftsCorrect Answer: 1. Draft hoods control the draft from the burner to maintain a constant (not excessive) airflow through the burner. 2. Draft hoods deflect down drafts coming down the chimney.Response Feedback: [None Given] Question 10
What is the implication of poor slope?Selected Answer: Exhaust spillage into the houseCorrect Answer: Exhaust spillage into the house.Response Feedback: [None Given] Question 11
What is the maximum horizontal length of vent connectors for gas appliances? (rough rule of thumb)Selected Answer: 5 feet. 1 1/2 foot maximum horizontal run for every one inch of vent connector diameterCorrect Answer: Use 1.5 foot maximum horizontal run for every 1 inch of vent connector diameter.Response Feedback: [None Given] Question 12
What is the most common and serious implication of vent connector problems?Selected Answer: Condensation or spillage of combustion productsCorrect Answer: Exhaust products entering the house.Response Feedback: [None Given] Question 13
What is the proper slope for a vent connector?Selected Answer: minimum 1/4 inch per footCorrect Answer: The vent connector should upward going from the water heater at a minimum of 1/4 inch per foot.Response Feedback: [None Given] Question 14
How many screws should you find at connections in the vent connector?Selected Answer: 3 screwsAnswers: Response Feedback: Good workQuestion 15
Is it possible to manifold a vent from a natural draft gas burner and an induced draft burner?Selected Answer: YesAnswers: Response Feedback: Good workQuestion 16
Rust caused by condensation in a gas fired appliance vent system is usually found:Selected Answer: on the lower part of the vent connectorAnswers: Response Feedback: Good workQuestion 17
A 40,000 BTU per hour input water heater should connect to a chimney flue shared by a 100,000 BTU per hour furnace above (after) the furnace vent connector.Selected Answer: False
Answers: True
FalseResponse Feedback: That's not correctQuestion 18
B Vent type vent connectors require a 1 inch combustible clearance.Selected Answer: True
Answers: True
FalseResponse Feedback: Good workQuestion 19
Gas water heater vent connectors which are single wall require a 9 inch combustible clearance.Selected Answer: False
Answers: TrueFalse
Response Feedback: Good workQuestion 20
Steel is an acceptable vent connector material but aluminum is not.Selected Answer: False
Answers: TrueFalse
Response Feedback: Good workQuestion 21
The manifolding in the previous question should be as close as possible to the appliances.Selected Answer: False
Answers: TrueFalse
Response Feedback: Good work